2001 Efficacy and safety of capsular bending ring implantationto preventposterior capsule opacification
important clinical implications for IOL design and for strategiesto preventposterior capsule opacification
+ Menapace R , Sacu S , Georgopoulos M , Findl O , Rainer G , Nishi O. Efficacy and safety of capsular bending ring implantationto preventposterior capsule opacification
Akura J. Capsular bending ringto preventposterior capsule opacification
More ) Use of bipolar diathermyto preventposterior capsule opacification(1
Sustained release of 5-fluorouracil from chitosan nanoparticles surface modified intra ocular lensto preventposterior capsule opacification
1997 Double - masked prospective ocular safety study of a lens epithelial cell antibodyto preventposterior capsule opacification
misalignment within a silicone irrigation / aspiration tip Barros , Marcílio G(passive) caused byPosterior capsule tear
SSanguinetti G Double - masked prospective ocular safety study of a lens epithelial cell antibodyto preventposterior capsule opacification
1,587 184 - Long - term results of trypan blue dye irrigation in the capsular bagto preventposterior capsule opacification
2017 ) : 2746 - 2754 Product Used : AK024 , AK019 Gervais , Kristen J. " Evaluation of a biodegradable thermogel polymer for intraocular delivery of cyclosporine Ato preventposterior capsule opacification
using distilled water ( DWto preventposterior capsule opacification
the ability of the PEO coatingto preventposterior capsule opacification
Matsushima H , Iwamoto H , Mukai K , Obara Y. Active oxygen processing for acrylic intraocular lensesto preventposterior capsule opacification
J Cataract Refract Surg 2000;261537- 1542PubMed Link to Article4 + Meacock G Double - masked prospective ocular safety study of a lens epithelial cell antibodyto preventposterior capsule opacification
ArticlePubMedGoogle Scholar Meacock WR , Spalton DJ , Hollick EJ , Boyce JF , Barman S , Sanguinetti G : Double - masked prospective ocular safety study of a lens epithelial cell antibodyto preventposterior capsule opacification
Stabilizing the Nucleus with Viscoat , Ocular surgery News - 1988 Viscoat Technique HelpsPreventPosterior Capsule Rupture
Christopher S C Liu ... the best wayto preventposterior capsule opacification
drug delivery system ... a new wayto preventposterior capsule opacification
January 2018 , 66(1):174 - 175 January 2018 , 66(1):173 - 174 471 92 - January 2018 , 66(1):173 - 173 434 85 - January 2018 , 66(1):177 - 178 443 74 - Erratum : Long - term results of trypan blue dye irrigation in the capsular bagto preventposterior capsule opacification
the ability of an open capsule deviceto preventposterior capsule opacification
a post - operative proliferation of cells in the capsule bag(passive) is caused byPosterior capsule opacification
similar levels of laser treatment in rabbit lensesmay causerupture of the posterior capsule
R C Lieurance , A C Patel , Wen Wan , Richard Beatty , R L Kash , David J. Schanzlin Use of a polylysine - saporin conjugateto preventposterior capsule opacification
proliferation and migration of residual lens epithelial cells into the visual axis(passive) caused byposterior capsule opacification
proliferation , migration , and metaplasia to the fibroblasts of residual lens epithelial cells(passive) is caused byPosterior capsule opacification
a primary posterior laser - assisted capsulotomy ( PLC ... after IOL implantationto preventposterior capsule opacification
The problem with silicone ... implantationmay causerupture of the posterior capsule
Posterior capsular tear is a complication during cataract surgeryleadingto a rupture of the posterior capsule
Because the posterior capsule in these patients is thinned and weakened centrally , hydrodissection should never be performedcan createa posterior capsule rupture
In about 40 - 50 % of patients , the posterior portion of the capsule becomes hazy after cataract surgerycausingposterior capsule opacification
to vitreous lossleadingto vitreous loss
to a loss of visual acuitycan leadto a loss of visual acuity
from faulty instrumentation Temel , Mustafaresultingfrom faulty instrumentation Temel , Mustafa
to uveitis , cystoid macular edema , or retinal detachmentmight also leadto uveitis , cystoid macular edema , or retinal detachment
haziness in the left eye ... following surgery for a trauma - induced cataract repaired in 2006was causinghaziness in the left eye ... following surgery for a trauma - induced cataract repaired in 2006
from the proliferation and migration of lens epithelial cells , anterior capsule opacification , or ongrowth of lens epithelial cells onto the anterior surface of the IOL.11 Posterior capsule opacificationresultingfrom the proliferation and migration of lens epithelial cells , anterior capsule opacification , or ongrowth of lens epithelial cells onto the anterior surface of the IOL.11 Posterior capsule opacification
from forceful hydrodissection ( hydrorupturecan resultfrom forceful hydrodissection ( hydrorupture
the prolapse of vitreous bodycausesthe prolapse of vitreous body
in a dropped nucleusmay have resultedin a dropped nucleus
to part or all of the cataract falling into the back part of the eyecould leadto part or all of the cataract falling into the back part of the eye
injury to the easy passage of the graft into the tunnelcan causeinjury to the easy passage of the graft into the tunnel
from the phaco procedureresultingfrom the phaco procedure
in tightness and stiffness of the capsule and is calledresultsin tightness and stiffness of the capsule and is called